Comparing suppository mold variability which can lead to dosage errors for suppositories prepared with the same or different molds Article (Faculty180)

cited authors

  • Alexander, Kenneth S; Baki, Gabriella; Hart, Christine; Hejduk, Courtney; Chillas, Stephanie

description

  • Suppository molds must be properly calibrated to ensure accurate dosing. There are often slight differences between molds and even in the cavities within a mold. A method is presented for the calibration of standard aluminum 6-, 12-, 50-, or 100-well suppository molds. Ten different molds were tested using water for volume calibration, and cocoa butter for standardization involving establishing the density factor. This method is shown to be straightforward and appropriate for calibrating suppository molds.

authors

publication date

  • 2013

start page

  • 512

end page

  • 4

volume

  • 17